Incremental encoder interface RS 422 - Fieldbus function-/technology module 750-631/000-004
750-631/000-004
4050821248309
EAN/GTIN
DE 40917098
WEEE
Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Incremental encoder interface RS 422 750-631/000-004 Supply voltage at DC 24... 24V Type of...
more
Incremental encoder interface RS 422 - Fieldbus function-/technology module 750-631/000-004 – WAGO – 4050821248309: Incremental encoder interface RS 422 750-631/000-004 Supply voltage at DC 24... 24V Type of supply voltage DC Number of hardware interfaces Industrial Ethernet 0 Number of interfaces PROFINET 0 Number of hardware interfaces serial RS- 232 0, number of HW interfaces serial RS-422 1, number of HW interfaces serial RS-485 0, number of HW interfaces serial TTY 0, number of HW interfaces parallel 0, number of HW interfaces wireless 0, Number of HW interfaces USB 0 Number of HW interfaces others 0 Supports protocol for other bus systems System component Suitable for incremental value acquisition Suitable for absolute value acquisition Degree of protection (IP) IP20 Fieldbus connection via separate bus coupler possible, mounting rail mounting possible, explosion protection category for gas without, explosion protection category for dust without, width 24mm, height 64mm, depth 100mm, The terminal provides an interface for connecting any incremental encoder. A 16-bit counter with quadrature decoder and a 16-bit latch for the zero pulse can be read, set or activated. The meter reading is transmitted quickly and reliably to the PC, PLC and NC via the installed field bus. The Gate input allows the counter to be disabled. The voltage supply of the encoder can be tapped directly at terminal Ue/U0. The shield connection is routed directly to the DIN rail.
...
more
Supply voltage at DC | 24V |
Voltage type of the supply voltage | DC |
Number of functions | 2 |
Number of HW interfaces serial RS-422 | 1 |
With optical interface | no |
Supports protocol for TCP / IP | no |
Supports protocol for PROFIBUS | no |
Supports protocol for CAN | no |
Supports protocol for INTERBUS | no |
Supports protocol for ASI | no |
Supports protocol for KNX | no |
Supports protocol for MODBUS | no |
Supports data highway protocol | no |
Supports protocol for DeviceNet | no |
Supports protocol for SUCONET | no |
Supports protocol for LON | no |
Supports protocol for PROFINET IO | no |
Supports protocol for PROFINET CBA | no |
Supports protocol for SERCOS | no |
Supports protocol for EtherNet / IP | no |
Supports protocol for DeviceNet Safety | no |
Supports protocol for INTERBUS safety | no |
Supports protocol for PROFIsafe | no |
Supports protocol for SafetyBUS p | no |
Wireless standard Bluetooth | no |
Wireless standard WLAN 802.11 | no |
Radio standard GPRS | no |
Radio standard GSM | no |
Radio standard UMTS | no |
IO-Link master | no |
System component | yes |
Suitable for counting | no |
Suitable for weighing | no |
Suitable for temperature control | no |
Suitable for welding control | no |
Suitable for pressure control | no |
Suitable for NC | no |
Suitable for position detection | yes |
Suitable for CNC | no |
Suitable for SSI | no |
Suitable for incremental value acquisition | yes |
Suitable for absolute value acquisition | yes |
Suitable for flow control | no |
Suitable for flow measurement | no |
Suitable for railway control | no |
Suitable for cam control | no |
Suitable for flying saw | no |
Suitable for multi-axis control | no |
Suitable for single-axis control | no |
Suitable for multi-axis positioning | no |
Suitable for single-axis positioning | no |
Function block restart interlock | no |
Function block automatic reset | no |
Contactor control function block | no |
Function block EMERGENCY STOP | no |
Function block acknowledgment button | no |
Function block two-hand circuit | no |
Function block operating mode selection | no |
Function block access control | no |
IP protection) | IP20 |
Frequency measurement | no |
Rail mounting possible | yes |
Wall / direct mounting possible | no |
Front installation possible | no |
Rack mounting possible | no |
Suitable for safety functions | no |
Associated equipment (Ex ia) | no |
Associated equipment (Ex ib) | no |
Explosion protection category for gas | without |
Explosion protection category for dust | without |
Width | 24 mm |
Height | 100 mm |
Depth | 69.8 mm |
Cookie settings
This website uses cookies that are required for the technical operation of the website and always stored. Other cookies that enhance convenience when using this website, or that are intended for direct marketing or to simplify interaction with other websites and social networks, are only stored with your consent.
Configuration
Technically required
These cookies are required for the basic functions of the shop.
Accept all cookies
Amazon Pay
CSRF token
Cookie settings
Currency change
Customer recognition
Customer-specific caching
FACT-Finder tracking
Individual prices
Reject all cookies
Selected shop
Session
Wish list
Device recognition
Saferpay payments
PayPal payments
IP2location
Listing settings
Trustami
Wishlist
TagManager
Statistics and tracking
Criteo
Google analytics
Partner program
Custom tracking