Fieldbus coupler CANopen Eco D-Sub - Fieldbus basic device DC24V 750-348
750-348
4045454395964
EAN/GTIN
DE 40917098
WEEE
Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Fieldbus coupler CANopen Eco D-Sub 750-348 input voltage at DC 24... 24V, type of input voltage...
more
Fieldbus coupler CANopen Eco D-Sub - Fieldbus basic device DC24V 750-348 – WAGO – 4045454395964: Fieldbus coupler CANopen Eco D-Sub 750-348 input voltage at DC 24... 24V, type of input voltage DC, max. input current at DC 0.26A, number of HW interfaces Industrial Ethernet 0, number of interfaces PROFINET 0, number of HW -Interfaces serial RS-232 0, number of HW interfaces serial RS-422 0, number of HW interfaces serial RS-485 0, number of HW interfaces serial TTY 0, number of HW interfaces USB 0, number of HW -Interfaces parallel 0, number of HW interfaces wireless 0, number of HW interfaces other 1, supports protocol for DeviceNet, system components, degree of protection (IP) IP20, number of slots 1, with pluggable modules, digital I/O, with pluggable Assemblies, analog I/O, with pluggable assemblies, communication modules, with pluggable assemblies, function and technology modules, with pluggable assemblies, central modules, with pluggable assemblies, other, version of the electrical connection spring-loaded connection s, with electrical isolation, with bus coupler for modular station structure, DIN rail mounting possible, explosion protection category for gas ATEX gas explosion protection, cat. 3G, explosion protection category for dust ATEX dust explosion protection, cat. 3D, width 50mm, height 65mm, depth 97mm The ECO fieldbus couplers are designed for applications with a small data width in the process image. These are mainly applications with digital process data or applications in which only a few analog process data are used. The system is supplied directly at the coupler. The field supply is connected via a separate power terminal. The CANopen bus coupler recognizes all plugged-in I/O terminals and uses them to create a local process image. The local process image is divided into an input and an output data area. The process data can be read in via the CANopen bus and further processed in a controller. The process output data is output via the CANopen bus. The data of the analog terminals are mapped into the PDOs in the order of their position after the bus coupler. The bits of the digital terminals are combined into bytes and also mapped into the PDOs. If the number of digital I/Os is greater than 8 bits, the coupler automatically starts another byte. The entries in the object directory can be mapped to the 5 Rx PDOs and 5 Tx PDOs as required. The entire input and output data area can be transferred with the SDOs. Placeholder terminals can be set using software. Caution: Configuration files (EDS) required!
...
more
With integrated power supply | yes |
Input voltage at DC | 24V |
Type of input voltage | DC |
Max. Input current at DC | 0.26 A |
Number of HW interfaces other | 1 |
With optical interface | no |
Supports protocol for TCP / IP | no |
Supports protocol for PROFIBUS | no |
Supports protocol for CAN | yes |
Supports protocol for INTERBUS | no |
Supports protocol for ASI | no |
Supports protocol for KNX | no |
Supports protocol for MODBUS | no |
Supports data highway protocol | no |
Supports protocol for DeviceNet | no |
Supports protocol for SUCONET | no |
Supports protocol for LON | no |
Supports protocol for SERCOS | no |
Supports protocol for PROFINET IO | no |
Supports protocol for PROFINET CBA | no |
Supports protocol for EtherNet / IP | no |
Supports protocol for DeviceNet Safety | no |
Supports protocol for INTERBUS safety | no |
Supports protocol for PROFIsafe | no |
Supports protocol for SafetyBUS p | no |
Wireless standard Bluetooth | no |
Wireless standard WLAN 802.11 | no |
Radio standard GPRS | no |
Radio standard GSM | no |
Radio standard UMTS | no |
IO-Link master | no |
System component | yes |
IP protection) | IP20 |
Number of slots | 1 |
With pluggable assemblies, digital I / O | yes |
With plug-in modules, analog I / O | yes |
With plug-in modules, communication modules | yes |
With pluggable modules, central modules | yes |
With pluggable modules, miscellaneous | yes |
With electrical isolation | yes |
With bus coupler for modular station design | yes |
Rail mounting possible | yes |
Wall / direct mounting possible | no |
Front installation possible | no |
Rack mounting possible | no |
Suitable for safety functions | no |
Associated equipment (Ex ia) | no |
Associated equipment (Ex ib) | no |
Width | 49.5 mm |
Height | 96.8 mm |
Depth | 71.9 mm |
Cookie settings
This website uses cookies that are required for the technical operation of the website and always stored. Other cookies that enhance convenience when using this website, or that are intended for direct marketing or to simplify interaction with other websites and social networks, are only stored with your consent.
Configuration
Technically required
These cookies are required for the basic functions of the shop.
Accept all cookies
Amazon Pay
CSRF token
Cookie settings
Currency change
Customer recognition
Customer-specific caching
FACT-Finder tracking
Individual prices
Reject all cookies
Selected shop
Session
Wish list
Device recognition
Saferpay payments
PayPal payments
IP2location
Listing settings
Trustami
Wishlist
TagManager
Statistics and tracking
Criteo
Google analytics
Partner program
Custom tracking