Passive isolator 2-way 0(4)mA-20 mA - Isolation amplifier MACX MCR-SL-I-IILPSP
MACX MCR-SL-I-IILPSP
2905279
4046356944397
EAN/GTIN
DE 50738265
WEEE
Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.
Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Passive isolator 2-way 0(4)mA-20 mA MACX MCR-SL-I-IILPSP Number of input ranges -60 mV ... +60 mV...
more
Passive isolator 2-way 0(4)mA-20 mA - Isolation amplifier MACX MCR-SL-I-IILPSP – Phoenix – 2905279 – 4046356944397: Passive isolator 2-way 0(4)mA-20 mA MACX MCR-SL-I-IILPSP Number of input ranges -60 mV ... +60 mV 0, number of input ranges -100 mV ... +100 mV 0, number of Input ranges -300 mV ... +300 mV 0, number of input ranges -500 mV ... +500 mV 0, number of input ranges -1 V ... +1 V 0, number of input ranges -2 V ... + 2 V 0, number of input ranges -2.5 V ... +2.5 V 0, number of input ranges -5 V ... +5 V 0, number of input ranges -10 V ... +10 V 0, Number of input ranges -20 V ... +20 V 0, Number of input ranges 0 mV ... 60 mV 0, Number of input ranges 0 mV ... 100 mV 0, Number of input ranges 0 mV ... 200 mV 0, Number of input ranges 0 mV ... 300 mV 0, number of input ranges 0 mV ... 500 mV 0, number of input ranges 0 V ... 1 V 0, number of input ranges 0 V ... 2 V 0, number of Input ranges 0 V ... 2.5 V 0, number of input ranges 0 V ... 5 V 0, number of input ranges 0 V ... 10 V 0, number of input ranges 0 V ... 20 V 0, number of Input ranges 0 V ... 24 V 0, number of input ranges 0 V ... 30 V 0, number of input ranges 1 V ... 5 V 0, number of input ranges 2 V ... 10 V 0, number of input ranges + 5 V ... -5 V 0, number of input areas +10 V ... -10 V 0, number of input areas 5 V ... 0 V 0, number of input areas 5 V ... 1 V 0, number of Input ranges 10 V ... 0 V 0, number of input ranges 10 V ... 2 V 0, number of input ranges 0 mA ... 5 mA 0, number of input ranges 0 mA ... 10 mA 0, number of input ranges 0 mA ... 20 mA 1, number of input ranges 4 mA ... 20 mA 1, number of input ranges -5 mA ... +5 mA 0, number of input ranges -10 mA ... +10 mA 0, number of Input ranges -20 mA ... +20 mA 0, number of input ranges 20 mA ... 0 mA 0, number of input ranges 20 mA ... 4 mA 0, number of output ranges -60 mV ... +60 mV 0, Number of output ranges -100 mV ... +100 mV 0, Number of output ranges -300 mV ... +300 mV 0, Number of output ranges -500 mV ... +500 mV 0, Number of output ranges -1 V .. +1 V 0, number of output ranges -2 V ... +2 V 0, number of output ranges -2.5 V ... +2.5 V 0, number of output ranges -5 V ... +5 V 0, number of output ranges -10 V ... +10 V 0, number of output ranges -20 V ... +20 V 0, number of output ranges 0 mV ... 60 mV 0, number of output ranges 0 mV ... 100 mV 0, number of output ranges 0 mV ... 200 mV 0, number of output ranges 0 mV ... 300 mV 0, number of output ranges 0 mV ... 500 mV 0, number of output ranges 0 V ... 1 V 0, number of output ranges 0 V ... 2 V 0, number of output ranges 0 V ... 2.5 V 0, number of output ranges 0 V ... 5 V 0, number of output ranges 0 V ... 10 V 0, number of output ranges 0 V ... 20 V 0, number of output ranges 0 V ... 24 V 0, number of output ranges 0 V ... 30 V 0, number of output ranges 1 V ... 5 V 0, Number of output ranges 2 V ... 10 V 0, number of output ranges +5 V ... -5 V 0, number of output ranges +10 V ... -10 V 0, number of output ranges 5 V ... 0 V 0, number of output ranges 5 V ... 1 V 0, number of output ranges 10 V ... 0 V 0, number of output ranges 10 V ... 2 V 0, number of output ranges 0 mA ... 5 mA 0, Number of output ranges 0 mA ... 10 mA 0, Number of output ranges 0 mA ... 20 mA 1, Number of output ranges 4 mA ... 20 mA 1, Number of output ranges -5 mA ... +5 mA 0, Number of output ranges -10 mA ... +10 mA 0, Number of output ranges -20 mA ... +20 mA 0, Number of output ranges 20 mA ... 0 mA 0, Number of output ranges 20 mA ... 4 mA 0, number of channels 1, height 116.59mm, width 12.78mm, depth 113.7mm, burden 1375000 ... 1375000Ohm, operating temperature -40 ... 85°C, temperature drift 0.002%/K, device design built-in device, version of electrical connection other, mounting type other, protection class (IP) IP20, single-channel input loop-powered 2-way isolator with pluggable connection technology for galvanic isolation of analog signals. Input signal = output signal: 0(4) mA ... 20 mA. Push-in connection technology.
...
more
Number of input ranges 0 mA ... 20 mA | 1 |
Number of input ranges 4 mA ... 20 mA | 1 |
Number of output ranges 0 mA ... 20 mA | 1 |
Number of output ranges 4 mA ... 20 mA | 1 |
Amount of channels | 1 |
Alarm output | no |
Intrinsically safe according to EN 60947-5-6 NAMUR | no |
Galvanic isolation between the inputs | no |
Height | 116 mm |
Width | 12.5 mm |
Depth | 114.5 mm |
Burden | 2,39999999 A |
Operating temperatur | -40..85 °C |
Temperature drift | 0.002 %/K |
Device Type | Built-in device |
Execution of the electrical connection | other |
Mounting | Snap-on mounting rail |
IP protection) | IP20 |
Cookie settings
This website uses cookies that are required for the technical operation of the website and always stored. Other cookies that enhance convenience when using this website, or that are intended for direct marketing or to simplify interaction with other websites and social networks, are only stored with your consent.
Configuration
Technically required
These cookies are required for the basic functions of the shop.
Accept all cookies
Amazon Pay
CSRF token
Cookie settings
Currency change
Customer recognition
Customer-specific caching
FACT-Finder tracking
Individual prices
Reject all cookies
Selected shop
Session
Wish list
Device recognition
Saferpay payments
PayPal payments
IP2location
Listing settings
Trustami
Wishlist
TagManager
Statistics and tracking
Criteo
Google analytics
Partner program
Custom tracking