Diffuse mode sensor with HGA - Light scanner with background masking GLV18-8-H-120/73/120

Pepperl + Fuchs - GLV18-8-H-120/73/120 - Diffuse mode sensor with HGA - Light scanner with background masking GLV18-8-H-120/73/120
Photo source: fig. possibly similar
GLV18-8-H-120/73/120 212930 4050143027309 EAN/GTIN DE 19020045 WEEE

Our best price
$115.28 incl. VAT ($0.00)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Diffuse mode sensor with HGA GLV18-8-H-120/73/120, setting range=40..120 mm, scanning... more
Diffuse mode sensor with HGA - Light scanner with background masking GLV18-8-H-120/73/120 – Pepperl + Fuchs – 212930 – 4050143027309: Diffuse mode sensor with HGA GLV18-8-H-120/73/120, setting range=40..120 mm, scanning range=10..120 mm, triangulation=background suppression, pre-failure message=no, with timer function=no, rated switching distance=120 mm , max. switching distance=120 mm, max. output current=100 mA, with reflector=no, analogue output 0 V ... 10 V=no, analogue output 0 mA ... 20 mA=no, analogue output 4 mA ... 20 mA =no, analog output -10 V ... +10 V=no, with other analog output=no, setting method=manual setting, with analog communication interface=no, with AS-Interface communication interface=no, with CANOpen communication interface=no, with DeviceNet communication interface =no, with communication interface Ethernet=no, with communication interface INTERBUS=no, with communication interface PROFIBUS=no, with communication interface RS-232=no, with communication interface RS-422=no, with communication interface RS-485=no, with communication interface elle SSD=no, with SSI communication interface=no, number of semiconductor outputs with signaling function=2, design of the electrical connection=M12 plug connector, design of the switching output=PNP/PNP, design of the switching function=complementary, equipment protection class=protection class 2, Explosion protection category for gas=none, explosion protection category for dust=none, housing design=cylinder, thread, sensor diameter=18 mm, sensor length=43.9 mm, tactile function=light/dark switching, material of the optical surface= Plastic, housing material=plastic, ambient temperature=-25..60 °C, switching frequency=500 Hz, rated control supply voltage Us at DC=10..30 V, voltage type=DC, with monitoring function of downstream devices=no, sensor wavelength=640 nm, type of light=red light unpolarized, with restart lock=no, suitable for safety functions=no, degree of protection (IP)=IP67, scanning range: 10 ... 120 mm, light emitter: LED, type of light: red, alternating light, 640 nm , signal output: 2 PNP, non-equivalent, short-circuit proof, open collectors, switching type: light/dark switching, connection: device plug M12 x 1, 4-pin, operating voltage: 10 ... 30 V DC, ambient temperature: -25 ... 60 ° C (-13 ... 140°F)
... more
Adjustment 40..120 mm
Operating distance 10..120 mm
Triangulation Background suppression
Failure warning no
With time function no
Rated operating distance 120 mm
Max. Switching distance 120 mm
Max. Output current 100mA
With reflector no
Analog output 0 V ... 10 V no
Analog output 0 mA ... 20 mA no
Analog output 4 mA ... 20 mA no
Analogue output -10 V ... +10 V no
With other analog output no
Adjustment manual adjustment
With communication interface analog no
With communication interface AS-Interface no
With communication interface CANOpen no
With communication interface DeviceNet no
With communication interface Ethernet no
With communication interface INTERBUS no
With communication interface PROFIBUS no
With communication interface RS-232 no
With communication interface RS-422 no
With communication interface RS-485 no
With communication interface SSD no
With communication interface SSI no
Execution of the switching output PNP / PNP
Execution of the switching function complementary
Operating resource protection class Protection class 2
Explosion protection category for gas without
Explosion protection category for dust without
Housing construction Cylinder, thread
Diameter of the sensor 18 mm
Length of the sensor 43.9 mm
Key function light / dark switching
Material of the optical surface Plastic
Material of the housing Plastic
Ambient temperature -25..60 °C
Switching frequency 500 Hz
Rated control supply voltage Us at DC 10..30 V
Voltage DC
Wavelength of the sensor 640 nm
Light Source Red light unpolarized
With restart interlock no
Suitable for safety functions no
IP protection) IP67

Rate item

(0 reviews)
Read, write and discuss reviews... more
Customer review for "Diffuse mode sensor with HGA - Light scanner with background masking GLV18-8-H-120/73/120"
Write a review
Evaluations will be activated after verification.
Please enter these characters in the following text field.

The fields marked with * are required.