FI circuit breaker 16A 250V 30mA - Residual current breaker 2-p A 5530 FIB WW

A 5530 FIB WW 4011377148833 EAN/GTIN DE 64244154 WEEE

Our best price
$135.47 incl. VAT ($0.00)
$194.65 (-30.4% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
FI circuit breaker 16A 250V 30mA A 5530 FIB WW Number of poles 2, rated voltage 230V, rated... more
FI circuit breaker 16A 250V 30mA - Residual current breaker 2-p A 5530 FIB WW – Jung – 4011377148833: FI circuit breaker 16A 250V 30mA A 5530 FIB WW Number of poles 2, rated voltage 230V, rated current 16A, rated residual current 0.03A, mounting type built-in, residual current type A, short-circuit strength (Icw) 3kA, surge current strength 0.25kA, frequency 60 Hz, protection class (IP ) IP21, installation depth 32mm, ambient temperature during operation -25 ... 40°C, connectable conductor cross-section solid 15 ... 2.5mm², material: thermoplastic according to DIN EN 61008-1 (VDE 0664-10) and DIN EN 61008- 2-1 (VDE 0664-11) Rated residual current: 30 mA with spring terminals for rigid conductors up to 2.5 mm2 not suitable for mounting in surface-mounted caps To be connected to 2 or 3-wire supply lines. Installation in a 60 mm flush-mounted box (deep box recommended). Stationary protective device with voltage-independent function. The sockets connected to the output terminals are protected in accordance with DIN VDE 0100-410. However, the electrical installation up to the FI circuit breaker is not protected!
... more
Number of poles 2
Rated voltage 230V
Rated current 16 A
Rated fault current 0.03 A
Mounting Built-in
Fault current type A
Selective type no
Short time delayed type no
Short-circuit strength (Icw) 3 kA
Surge current resistance 0.25 kA
With locking device no
Frequency 60 Hz
IP protection) IP20
Depth 32 mm

Rate item