Sheathed cable halogen-free drum 500m - Power cable < 1kV, fix installation NHXMH-O 2x 1,5 Dca

Diverse - NHXMH-O 2x 1,5 Dca - Sheathed cable halogen-free drum 500m - Power cable < 1kV, fix installation NHXMH-O 2x 1,5 Dca
Photo source: fig. possibly similar
Photo source: fig. possibly similar
NHXMH-O 2x 1,5 Dca NHXMH-O 2x 1,5 Dca T.500

$1.29 incl. VAT ($0.00)

4-5 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
NHXMH-O 2x 1.5 Dca T.500 sheathed cable halogen-free. Conductor material copper, nominal... more
Sheathed cable halogen-free drum 500m - Power cable < 1kV, fix installation NHXMH-O 2x 1,5 Dca – Diverse – NHXMH-O 2x 1,5 Dca T.500: NHXMH-O 2x 1.5 Dca T.500 sheathed cable halogen-free. Conductor material copper, nominal conductor cross-section 1.5mm², conductor class class 1 = solid, number of cores 2, core insulation material other, specification core insulation polyethylene (PE), max. max. conductor temperature 70°C, protective sheath without, armouring/armouring without, sheath material other, sheath color grey, reaction to fire class according to EN 13501-6 Dca, insulation integrity no, according to VDE 0250. Halogen-free sheathed cable with improved behavior in the event of fire according to DIN 0472 part 813 Low fire propagation according to DIN VDE 0472 part 804/test type C. Minimum smoke development according to DIN VDE 0472 part 816. They are used where damage to people and material must be prevented in the event of fire due to a high concentration of property, eg in industrial plants, communal facilities, hotels , airports, subways, train stations, hospitals, department stores, banks, schools, theatres, cinemas, high-rise buildings, control centers, etc. Suitable for installation in dry, damp or wet rooms, for laying over, on, in and under plaster and in masonry and in concrete, but not for direct embedding in vibrated or tamped concrete. They are also suitable for outdoor use provided they are protected from direct sunlight. Core color code according to VDE 0293. Max. operating temperature 70 °C. Copper base: EUR 150 per 100 kg
... more
Conductor material Copper
Conductor cross-section 1.5 mm²
Conductor category Kl.1 = solid
Number of cores 2
Core insulation material other
Specification Core insulation Polyethylene (PE)
Core identification Color
With protective conductor no
Permitted max. conductor temperature 70 °C
Umbrella no
Drain wire no
Cover without
Armouring / reinforcement without
jacket material other
Coat Color gray
Fire behavior class according to EN 13501-6 Dca
Outer diameter approx. 8.5 mm
Rated voltage U0 300V
Rated voltage U 500V
Mass 110 kg/km