Heating/cooling circuit controller 2-fold 0-10V man REG - KNX Heating actuator for home automatio...

HCC/S2.1.2.1 2CDG110219R0011 4016779011624 EAN/GTIN DE 91945327 WEEE

Our best price
$321.93 incl. VAT ($0.00)
$606.16 (-46.89% RRP***)

15-16 days* (USA)

Safety and hazard information
Please note that electrotechnical work may only be carried out by qualified electricians or under their guidance and supervision. Observe any deviating country-specific electrical installation standards and regulations and seek advice from a local electrician.In addition, observe more current safety instructions and regulations for the products on the manufacturer's side or the product descriptions and installation instructions on the manufacturer's side.

Devices with a connected load of > 380V/400V require a heavy current connection and may only be connected by an approved electrical company. Devices with a power rating > 12kW require the approval of your grid operator (Germany, other countries may differ).
read more
show less
Heating/cooling circuit controller 2-fold 0-10V man REG HCC/S2.1.2.1 bus system KNX, other bus... more
Heating/cooling circuit controller 2-fold 0-10V man REG - KNX Heating actuator for home automatio... – ABB – 2CDG110219R0011 – 4016779011624: Heating/cooling circuit controller 2-fold 0-10V man REG HCC/S2.1.2.1 bus system KNX, other bus systems without, mounting type REG, width in modular units 8, with bus coupling, control variable constant, valve protection function, manual switching, number of binary inputs 6 , max. switching current (resistive load) 5A, number of outputs 4, max. output current 5A, switching voltage 230... 230V, degree of protection (IP) IP20, min. depth of device box 64.5mm, for controlling a heating or cooling circuit . The device has 2 channels, each with an analog output for controlling the 3-way mixer valve (0 to 10 V) of a heating or cooling circuit. The device also has a relay output (5 A) for switching the circulation pump. The status of the pump can be monitored via 3 binary signal inputs (via potential-free contacts) and this feedback can be included in the control of the pump. The flow and return temperatures are measured and used by the integrated controller to calculate the valve control value. The setpoint is received via the KNX bus. Channel bundling makes it possible to control systems with double pumps. The HCC/S 2.1.2.1 has an easy-to-use on-site control. The ABB i-bus tool can be used for extended diagnostic functions and improved commissioning.
... more
Bus system KNX yes
Bus system KNX radio no
Bus system radio bus no
Bus system LON no
Bus system Powernet no
Other bus systems without
Radio bidirectional no
Mounting REG
Width in division units 8th
With bus coupling no
Bus module removable no
Control variable steady yes
Switching manipulated variable no
Valve protection function yes
Manual gearshift yes
Number of digital inputs 10
Max. Switching current (resistive load) 5 A
Number of exits 4
Max. Output current 5 A
Switching voltage 0..10V
IP protection) IP20
Min. depth of the device socket 64.5 mm